31/03/2019
Performance Characterization Of A Simultaneous Positive and Negative Ion Detector For Mass Spectrometry ApplicationsRecent advances in shadow mask and laser ablation technology have opened up new possibilities for making compact segmented detectors.The active area of the microchannel plate can now be effectively partitioned into multiple areas offering specific performance capabilities. Separate areas could be effectively biased to preferentially detect either positively or negatively charged particles.
31/03/2019
Quantum Sub Miniature MCP DetectorThe Development of a Micro-Miniature Microchannel Plate Based Detector For Mass Spectrometry Applications
31/03/2019
Raising the Bar on Electron Multiplier Operation at Elevated PressuresThis paper explores the boundaries of electron multiplication for amplification at pressures above 1x10-4 Torr. Using gain, voltage and dark current measurements in differing multiplier geometries, the maximum operating pressure as a function of voltage and detector gain is presented.
31/03/2019
Reducing Detector Time Jitter to improve Mass Resolution in a Time of Flight Mass SpectrometerThe effects of combining previous research regarding optimizing Microchannel Plates with regards to both optimal resolution parameters and MCP flatness to increase mass resolution by as much as 15%.
31/03/2019
The Development of a High Speed Detector for Time-of-Flight Mass SpectrometryTime of Flight Mass Spectroscopy has become the most widely used technique for identifying very large organic molecules. Recently, companies have started designing table top and portable TOF-MS instruments as the market has shifted. In this presentation, you will learn more about the origins of Time of Flight Mass Spectrometry and how our detectors support these instruments.
31/03/2019
The Development of a Micro-Miniature Microchannel Plate Based Detector For Mass Spectrometry ApplicationsThis paper discusses the development of an MCP-based detector less than 9mm in diameter with a gain of at least 100X. A new technology using brazed ceramic to metal seals was used. Noise tests were done to determine the effects of use in poor vacuum environments.
31/03/2019
The Development of a Novel Cold Electron SourceMicrochannel Plates can be modified to function as spontaneous electron emitters. These electron generators are created by altering the microstructure of the MCP channel, so that spontaneously emitted electrons can be produced, causing cascading secondary electrons. The emission current can be varied over a broad range.
31/03/2019
The Development of a Novel Electron Multiplier with an Onboard Integral High Voltage Power Supply for use in Mass SpectrometersThis paper characterizes the performance of using an onboard integral high voltage power supply in comparison to a traditional external rack-mounted power supply.
31/03/2019
The Development of Novel Resistive Glass Technology to Simplify and Improve Designs in Analytical InstrumentsA new proprietary reduced led silicate glass can be made into geometric glass structures. The glass has resistive properties and can create a very uniform electric field to more effectively guide or attract charged particles. The glass can also have thin film metallization points. These geometric structures can be used for drift tubes, ion guides, collision cells, reflectron lenses and more.
31/03/2019
The Development of Novel Resistive Glass Technology to Simplify Ion Reflectron Lenses, Ion Guides, Drift Tubes and Ion Source Designs in Analytical InstrumentsThis paper examines how Resistive Glass can be used to manufacture reflectron lenses, ion guides, drift tubes and ion sources with similar performance and significantly simplifying the analtyical instrument's design.
31/03/2019
The development of the 2 micron pore Microchannel plateAn in-depth review of MCP history leading to the development, fabrication and quantification of a 2 micron pore microchannel plate. This new plate allows for a high speed detector with high spatial resolution.
13/06/2024
Custom Mass31/03/2019
The Effects of Endspoiling Variations on MCP PerformanceThis paper discusses various variations of endspoiling on microchannel plates (MCPs) to evaluate the effects on performance. Gain and spatial resolution variances were tested in both single MCP and Cheveron configurations.
31/03/2019
Why Choose Channeltron® Electron Multipliers?Photonis is the original manufacturer of all Channeltron® electron multipliers for use in a variety of analytical instruments. Our Channeltron® technology provides the highest dynamic range and sensitivity to ensure that your instrument is performing as efficiently as possible. As demonstrated in Figure 1, Channeltrons® directly detect and amplify energetic photons and charged particles such...
08/04/2019
The Development of Novel Resistive Glass Technology to Simplify Ion Reflector Lenses, Ion Guides, Drift Tubes and Ion Source Designs in Analytical InstrumentsLearn more about this innovative technology along with our other Resistive Glass products by downloading this presentation.